Toray RO layers (accessible in 4-inch, 8-inch, and 16-inch distances across) are utilized for metropolitan, mechanical, and commercial applications.

For person layer determination by application or layer sort, it would be ideal if you utilize the layer item look include.

TM Series

Series Model Diameter Product Flow
Rate
Rejection Net
Thickness
(inch) (m3/d) (gpd) (%) (mil)
TM700D
(High Rejection)
TM710D 4 9.8 2,600 99.8 34
TM720D-400 8 41.6 11,000 99.8 34
TM720D-440 8 45.8 12,100 99.8 28
TMG(D)
(Low Pressure)
TMG10D 4 10.0 2,650 99.7 34
TMG20D-400 8 45.8 12,100 99.7 34
TMG20D-440 8 50.3 13,300 99.7 28
TMHA
(Ultra Low Pressure)
TMH10A 4 9.1 2,400 99.3 34
TMH20A-400C 8 41.6 11,000 99.3 34
TMH20A-440C 8 45.7 12,100 99.3 28

TBW Series

Series Model Diameter Product Flow
Rate
Rejection Net
Thickness
(inch) (m3/d) (gpd) (%) (mil)
TBW-HR
(Ultra Low Pressure,
High Neutral Molecule Rejection)
TBW-440HR 8 31 8,200 99.8 28

SU Series *For replacement only

Series Model Diameter Product Flow
Rate
Rejection Net
Thickness
(inch) (m3/d) (gpd) (%) (mil)
TS
(Heat Sanitized)
SU-710T 4 6.5 1,700 99.4 37
SU-720TS 8 26.0 6,900 99.4 34
SUL-G10TS 4 5.0 1,300 99.5 37
SUL-G20TS 8 30.0 7,900 99.5 34
SUL-G20FTS 8 36.0 9,500 99.5 28

Water Specialist 1" EI Control Specifications

Toray makes seawater RO films in 4, 8, and 16-inch breadths that can treat seawater or tall saltiness water sources with > 10,000 ppm. Our items are broadly utilized for mega desalination plants, watermakers for private water crafts and commercial ships, and treating mining following water for reuse or release.

TM Series

Series Model Diameter Product Flow
Rate
Rejection Net
Thickness
(inch) (m3/d) (gpd) (%) (mil)
TM800M
(Standard)
TM820M-400 8 26.5 7,000 99.8 34
TM820M-440 8 29.2 7,700 99.8 28
TM800V
(Low Energy)
TM810V 4 7.2 1,900 99.8 34 
TM820V-400 8 34.1 9,000 99.8 34
TM820V-440 8 37.5 9,900 99.8 28
TSW-LE
(Super Low Energy)
(*600 psi)
TSW-400LE 8 23.0* 6,100* 99.60* 34
TSW-440LE 8 25.3* 6,700* 99.60* 28
TM800K
(Highest Rejection)
TM820K-400 8 21.9 5,800 99.86 34
TM820K-440 8 24.2 6,400 99.86 28

FOULING POTENTIAL WATER

Toray's moo fouling RO layers successfully treat nourish water sorts with tall fouling inclination. Combined with our restrictive solid "D-family" layer formula for improved chemical resilience, Toray's film components offer one of the foremost solid execution beneath challenging conditions. Perfect for wastewater treatment and water reuse applications.

TM Series

Series Model Diameter Product Flow
Rate
Rejection Net
Thickness
(inch) (m3/d) (gpd) (%) (mil)
TLF
(Ultra Low pressure, Low Fouling)
TLF-400DG 8 43.5 11,500 99.5 34
TMLD
(Low Fouling, High Tolerance)
TML10D 4 7.2 1,900 99.8 34
TML20D-400 8 39.7 10,500 99.8 34

SPARE PARTS

Discover save parts for Toray's layer components that are required to appropriately and securely work your layer treatment framework.

INTERCONNECTOR

Model Product No. Connection
Type
Brand Seal Type Permeate
tube
diameter
Material Temperature
[℃]
Interconnector Toray
TM 4 inch
IC4TM ND Toray O-Ring 0.75 PVC 80
Interconnector Toray
TM 8 inch
IC8TM ND Toray O-Ring 1.125 m-PPE 80
Interconnector Toray
SU / SC 4 inch
IC4SU OD Toray O-Ring 0.827 PVC 80
Interconnector Toray
SU / SC 8 inch
IC8SU OD Toray O-Ring 1.26 m-PPE 80

O-RING SEAL

Model Product No. Brand Seal Type Cord Thickness Nominal Diameter Material Temperature Seal Shore
[℃] [Shores]
O-Ring Toray
TM 4 inch NBR
P19TM-4 NBR Dichtomatik O-Ring 2.62 18.62 NBR 80 70
O-Ring Toray
TM 8 inch NBR
(not for G&H type)
P23TM-8 NBR Dichtomatik O-Ring 2.62 23.47 NBR 80 70

MEMBRANE BRINE SEAL

Model Product No. Brand Seal Type Cord Thickness Nominal Diameter Material Temperature Seal Shore
[℃] [Shores]
Brine Seal
TM/SU 4 inch
BS4TM Toray V-Seal 5 100 EPT 80 90
Brine Seal
TM 8 inch
BS8TM Toray V-Seal 7.9 178.2 EPT 80 90

NANOFILTRATION

Nanofiltration films permit for distinctive dismissals: monovalent and divalent. It is conceivable to saturate specifically due to this include. The most applications are PR arrangements, colors, extraordinary chemicals, costly crude fabric recuperation and pretreatment for expelling parts of monovalents: Tone-ions and dismissing divalent Tone-ions in seawater forms.

Model Flow Rate
(GPD,m3/d)
NaCl
Rejection(%)
MgSO4
Rejection (%)
Diameter/
Length (inch)
Test Conditions
NE8040-40* 12,000 (45.4) 20-40 99.0 8.0 / 40 NE Standard
NE8040-70* 9,000 (34.1) 30-70 99.0 8.0 / 40 NE Standard (MgSO4)
NE8040-90* 8,000 (30.3) 90-97 8.0 / 40 NE Standard
NE8040-ARM 5,400 (20.4) 99.0 8.0 / 40 NE Standard (MgSO4)
NE8040-SRM 8,500 (32.2) 99.5 8.0 / 40 NE Standard (MgSO4)
NE4040-40* 2,500 (9.5) 20-40 99.0 4.0 / 40 NE Standard
NE4040-70* 1,900 (7.2) 30-70 99.0 4.0 / 40 NE Standard
NE4040-90* 1,700 (6.4) 90-97 4.0 / 40 NE Standard (NaCl)
NE4040-ARM 1,100 (4.2) 99.0 8.0 / 40 NE Standard (MgSO4)
NE4040-SRM 1,800 (6.8) 99.5 8.0 / 40 NE Standard (MgSO4)
  • NE Standard test conditions: NaCl 2,000 mg/L, Pressure 75 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
  • MgSO4 rejection test conditions: MgSO4 2,000 mg/L, Pressure 75 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
  • The stated data were obtained after 30 minutes of operation

RESIDENTIAL

Water is one of the foremost basic components for supporting human life. In any case, we confront wellbeing dangers from presentation to microbial & different contaminants that will be display within the water we drink. With the utilize of CSM’s Private RO Membranes, 100% of infections and over 99% of chemical substances are expelled meaning we are able appreciate clean, incredible tasting and most vitally secure water at domestic.

Model Flow Rate
(GPD,L/day)
Salt Rejection (%) Diameter/
Length (inch)
Test Conditions
RE3512-900 900 (3,407) 95.0 3.5 / 12 Household Standard at 80 psi, 40% Recovery
RE3512-TK 600 (2,271) 95.0 3.5 / 12 Dry Integrity Test
RE3012-800 800 (3,028) 96.0 3.5 / 12 Household Standard at 80 psi, 40% Recovery
RE3012-500 500 (1,893) 97.0 3.0 / 12 Dry Integrity Test
RE2812-450 450 (1,703) 96.0 2.8 / 12 Household Standard
RE2812-300* 350 (1,325) 97.0 2.8 / 12 Household Standard
RE2812-HR+* 300 (1,136) 99.0 2.8 / 12 Household Standard at 30% Recovery
RE2812-CE 220 (833) 97.0 2.8 / 12 Household Standard
RE2012-400* 400 (1,514) 96.0 2.0 / 12 Household Standard at 80 psi
RE2012-150 150 (567.8) 98.0 2.0 / 12 Household Standard
RE2012-100 110 (416) 98.0 2.0 / 12 Household Standard
RE2012-LPF 60 (227) 93.0 2.0 / 12 Household LP
RE2012-LP* 50 (189) 93.0 2.0 / 12 Household LP
RE1812-80* 100 (379) 98.0 1.8 / 12 Household Standard
NE1812-70 90 (341) 40-70 (95%) 1.8 / 12 NF Household Standard
RE1812-HR+* 80 (303) 99.0 1.8 / 12 Household Standard at 30% Recovery
RE1812-50* 70 (265) 98.0 1.8 / 12 Household Standard
RE1812-LP 30 (114) 93.0 1.8 / 12 Household LP
RE1812-60* 80 (303) 98.0 1.8 / 12 Household Standard
RE1810-80* 80 (303) 98.0 1.8 / 10 Household Standard

Uf Residential Elements

Model Flow Rate
(GPD,m3/d)
Molecular Weight
Cut Off (MWCO)
Diameter/
Length (inch)
Test Conditions
UE1810* 200 (757) 100K 1.8 / 10 20 psi, Pure Water
UE2010* 450 (1,703) 100K 2.0 / 10 20 psi, Pure Water
  • Household Standard test conditions: NaCl 200 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
  • Household LP test conditions: NaCl 100 mg/L, Pressure 20 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
  • Dry Integrity test conditions: NaCl 200 mg/L, Pressure 60~80 psig, Temperature 25°C, pH 6.5-7.0 Recovery 30~40%
  • NF Household Standard test conditions: MgSO4/NaCl 250 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
  • The stated data were obtained after 30 minutes of operation

Water Treatment Components
Contact Us

Do you have a question about our products or would you like advice for your application?

We will help you!

Contact Us +49 621 87951 0
Drop a message

Fill out the form below and for specialist will be touch.